Calculator — Office & Work
Office Space Calculator
How much office space a team needs — workstations and private offices by benchmark, plus meeting space and 25% circulation.
Inputs
Results
Adjust the inputs to see your result.
About this calculator
Office space is four numbers added together: the workstations, the private offices, the meeting rooms, and the circulation that connects them. This calculator builds all four from headcount and the standard planning benchmarks — 50–75 sq ft per workstation, 150–200 sq ft per office, a meeting allowance and 25% circulation — and reports the total and the per-person figure.
What this number means
Office space is four numbers added together, not one: the workstations, the private offices, the meeting rooms, and the circulation that connects them — corridors, lobbies and the space around the desks. The first two come from headcount and a per-person benchmark; the last two are percentages of that subtotal, which is how space planners actually build an office brief.
The benchmarks are the industry's standard planning ranges: 50–75 sq ft per open workstation and 150–200 sq ft per private office, a 10–20% meeting allowance, and 25% circulation on top of everything else. A 24-person office at the standard settings needs about 2,731 sq ft — roughly 114 sq ft per person, which sits in the middle of the 100–150 sq ft per person range most modern offices land in.
The formula
- Workstation area = workstation staff × sq ft per workstation (50 / 60 / 75)
- Private office area = office staff × sq ft per office (150 / 175 / 200)
- Subtotal = workstation area + office area
- Meeting allowance = subtotal × 10%, 15% or 20%
- Circulation = (subtotal + meeting) × 25%
- Total = subtotal + meeting + circulation · Per person = total ÷ headcount
Worked example
20 workstation staff at 60 sq ft and 4 private offices at 175 sq ft, 15% meeting allowance.
- Workstations: 20 × 60 = 1,200 sq ft
- Private offices: 4 × 175 = 700 sq ft
- Subtotal: 1,200 + 700 = 1,900 sq ft
- Meeting allowance: 1,900 × 15% = 285 sq ft
- Circulation: (1,900 + 285) × 25% = 546.25 sq ft
- Total: 1,900 + 285 + 546.25 = 2,731.25 sq ft — 113.80 sq ft per person (24 people)
Assumptions and limitations
- Benchmarks are standard office-planning ranges: workstations 50–75 sq ft per person, private offices 150–200 sq ft, meeting allowance 10–20% of workspace area, circulation 25% of the total so far. They are planning estimates, not a building-code calculation.
- Areas are usable area inside the suite — the space you actually occupy. Rentable area adds the building's share of common areas (lobbies, elevator cores, shared restrooms), typically another 10–20% on top of the total here.
- The per-person figure is a sanity check: most modern offices land at 100–150 sq ft per person all-in. Well below 100 usually means benching or hot-desking; well above 150 usually means many private offices or generous meeting space.
- Hot-desking changes the maths: if not everyone is in on the same day, size workstations to the peak number of people in the office at once, not the total headcount — and use the Workstation Count Calculator to check how many desks a given floor actually holds.
Frequently asked questions
About 100–150 sq ft per person all-in, once meeting rooms and circulation are included. The worked example — 20 workstations at 60 sq ft plus 4 private offices — comes to 113.80 sq ft per person. Open-plan benching lands near 100; private-office-heavy layouts land near 150.
50–75 sq ft per open workstation is the standard planning benchmark: 50 sq ft for compact benching, 60 sq ft for a standard workstation, 75 sq ft for a generous one with storage. That is the desk plus its share of the aisle and personal storage — before meeting rooms and circulation are added.
It is the share of the suite given over to corridors, lobbies, restrooms and the space people walk through — space nobody sits in but everybody needs. Planners add 25% of the workspace + meeting area; a deep, inefficient floor plate can need more.
10–20% of the workspace area is the standard allowance — 15% for a typical mix of one conference room plus a huddle room or two. Meeting-heavy teams (sales, consulting) should use 20%; a team that mostly meets by video can use 10%.
Usable area — the space inside your suite. Rentable area is what the landlord charges for, and it adds your share of the building's common areas (lobbies, elevator cores, shared restrooms), typically 10–20% more. Ask the landlord for the load factor and multiply the total here by it.
Size workstations to the peak number of people in the office at once, not total headcount — if 30 people share 20 desks on a rota, enter 20 workstation staff. Then check the floor with the Workstation Count Calculator to confirm the desks actually fit.